Pulmonary Function Testing
Metabolic Cart
Sleep diagnostics and therapy
SomnoStar
Smoke cessation
Nasal Insafflation Therapy
ویژگی ها
مشخصات
پیکربندی
Flow/Volume gas measurements
Flow/Volume
Type: Pneumotach
Range: 0–20 L/s
Resolution: 10 mL/s
Accuracy: 0.2–12 L/s, ±2%
Resistance: < 0.5 cmH2O/L/s (0.05 kPa/L/s) @ 10 L/s
CMRR: 60 dB at 50 Hz
Volume
Type: Digital integration
Range: 0–20 L
Accuracy: ±5 mL
CO analyzer
Type: Electro chemical cell
Range: 0–0.4%
Accuracy: 0.0003%
He analyzer
Type: Thermal conductivity
Range: 0–9.5%
Accuracy: 0.05%
Flash multi-gas*
Type: Non-dispersive
Infrared, thermopile
Range: 0–0.33% CO
0–0.33% CH4
0–0.33% C2H2†
Resolution: 0.0005% CO
0.0005% CH4
0.0005% C2H2†
Accuracy: ±0.003% CO
±0.003% CH4
±0.003% C2H2†
Transducers
Mouth pressure (PM)
Type: Piezo resistive
Range: ±204.5 cmH2O (20 kPa)
Accuracy: ±2%
Electrical requirements (typical system)
Voltage: 100–240 VAC
Frequency: 50/60 Hz
Phase: Single
Power: Max. 520 VA
Ground leakage current: < 300µA at rated voltage
Dimensions/Weight
Console with swivel-mounted desktop (outside the U.S.): 155 cm (H) x 100 cm (W) x 78 cm (D) (61" x 39" x 31")
Console/Cart (in the U.S. only): 78–112 cm (H) x 60 cm (W) x 62 cm (D) (31–44" x 23.5" x 24.5")
39.1 kg (86 lb)
Standards
Quality system registration: ISO 13485
FDA: 510(k) market clearance
MDD 93/42/EEC: CE marked
Electrical safety: EN 60601-1
EMC: EN 60601-1-2
Due to continual product innovation, CareFusion designs and specifications are subject to change without notice.
* Multi-Gas Analyzer included only with diffusing capacity testing applications
** Included with Cardio-Pulmonary Exercise Testing Application
X=Standard feature O=Optional feature | ||
---|---|---|
Pulmonary function testing | MS PFT | |
Spirometry/flow-volume/MVV | X | |
Flow-volume animation | X | |
Body plethysmography | O | |
Real-time single breath diffusion | X | |
Intra breath diffusion | X | |
NO diffusion | O | |
Airway resistance rocc | O | |
Respiratory drive, resp. muscle strength | O | |
Tidal breathing analysis | O | |
Compliance | O | |
Impulse oscillometry | O | |
Bronchial test incl. APS pro | O | |
Rhinomanometry | O | |
FRC-He rebreathing | X | |
DCO-rebreathing | O | |
ECG | O | |
Cardio-pulmonary exercise testing | O | |
JScope | O | |
Upgrade existing | O | |
Administrative programs | ||
Database | X | |
Database Tools | O | |
SQL database | O | |
Trend Report | X | |
Automatic Interpretation | O | |
Offline Entry | X | |
Online Data Transfer | O | |
Report Designer | X | |
Predicted Value Generation | X | |
Language Maker | X | |
User Parameters | O | |
User Predicted Values | X | |
Bronchial Test Generation | O | |
IntelliSupport | O | |
AMOS | O | |
Network Database | O | |
Interface for Hospital/Practice System | O |
شرکت پاسارگاد طب ایرسا
آدرس : تهران- خیابان کریم خان زند- خیابان قائم مقام فراهانی
نرسیده به میدان شعاع - پلاک 72 طبقه 3 واحد 5
تلفکس : 88835233-021
021-88812983